Contact our expert

Mihail Tamarkin
Product Manager +7 (915) 1997911
Alexander Shugarev
Product Manager+7 (916) 1568562

Softwares

BioXpert is a software tool to control bio-processes and to store the process data. The software is designed specifically for biotech researchers and operators in the production environment. The logi?cal structure of the program and the user-friendly interface allows the program to be used by anyone. That is why over 1,000 packages of our BioXpert software are in use worldwide. The software is easy to operate and has extensive functionality for monitoring, collecting and storing data and controlling processes.This allows any bioprocess to be easily optimized and controlled using Applikon software.

Various BioXpert versions have been developed based on international standards for use in either research and pilot plant or production environments. BioXpert Lite is designed for data collection, data storage and data presentation. The research version (BioXpert 2) offers maximum flexibility to set up and to modify processes. The pilot plant and production version (BioXpert XP) focuses on process repeatability and data security.

The most recent release BioXpert XP allows the user to operate the bioreactor systems in compliance with the FDA's 21 CFR part 11 guidelines. Via web browser technology the BioXpert XP data is accessable throughout a network using Remote Access. To create process reports in compliance with 21 CFR part 11 BioXpert XP uses a separate Report Generator.

21CFR

BioXpert is installed on a PC that can be part of a local network. Data from sensors and actuators is read by BioXpert from the local controllers and stored in the database. The data can be used for advanced process control in BioXpert .

Applications

BioXpert seamlessly integrates with Applikon and other makes of controllers and peripheral equipment to ena?ble you to get the maximum out of your cultivation system. Pre-defined recipes exist for microbial culture, mammalian cell culture and plant cell culture.

All process data and controller data can be stored at user-defined intervals.

Off-line meas?urements can be added to the process data to be used for calculations or advanced process control. BioXpert offers different ways of presenting your measured data trend  graph, table and bargraph presentation .

The on-line calculations of BioXpert can be used to calculate derived variables.

The statement editor and interpreter allow time and/or event based execution of advanced control strategies. Another option for supervisory control is the use of timed profiles.

Remote Access for BioXpert  XP makes pro?cess data accessible for monitoring throughout a network using web browser technology.

Specifications

Specifications BioXpert Lite BioXpert 2 BioXpert XP
GENERAL
Operating system Windows NT, 2000, XP, Vista, Windows 7 Windows NT, 2000, XP, Vista, Windows 7 Windows XP
Communication drivers include: ADI 1010,
ADI 1020,
ADI 1030,
ADI 1010,
ADI 1020,
ADI 1030,
ADI 1010,
ADI 1030,
ADI 1060,
ADI 1060
Ez-Control, Ez-Control, Ez-Control,
i-Control i-Control i-Control
Sartorius balance,
Sartorius
Sartorius balance,
Sartorius
(micro) DCU, (micro) DCU,
VG mass spec.
ADDA card ADDA card ADDA card
Measurement of process values from process controllers yes yes yes
Control of process setpoints in process controllers no yes yes
Starting and stopping of controlloops no yes yes
Programming of local process controllers no no yes
Reading of calibration data no no yes
21 CFR part 11 compliant no no yes
GAMP compliant yes yes yes
ISA S88 standard no no yes
Password protection no no yes
User definable access rights no no yes
Auto start after power failure no no yes
DATA MANAGEMENT
On line data collection yes yes yes
Off-line data collection yes yes yes
Additional drivers available separately no no yes
Data storage system Proprietary file format Proprietary file format SQL database
Minimum sampling frequency 1 minute 1 minute 1 second
Sample frequency selectable per parameter no no yes
Data export to Excell yes yes yes
Data export in ASCII format yes yes yes
Graph export in BMP format yes yes
Dynamic Data Link to other programs no No yes
On-line calculations using on-line and off-line data no yes yes
DATA DISPLAY
Line graphs yes yes yes
Maximum number of pens per graph
Bar graphs yes yes yes
Synoptic yes yes yes
Procedure flow chart no no yes
Combination of current and historic data in graphs yes yes
Combination of different active batches in graphs yes yes
Measured data table display yes yes yes
Scatter plots yes yes yes
Storage of predefined graph settings yes yes yes
SUPERVISORY CONTROL
Programming of time based actions no yes yes
Programming of event based actions no yes yes
Profiling of setpoints no yes yes
Manual setting of local control setpoints no yes yes
Recipe definition yes
OTHER
Notebook for process and equipment remarks yes yes yes
Event viewer for system comments yes yes yes
Audit trail no no yes
Batch reports supported no no yes